Quantcast
Channel: Solving, solving\ - Latest Discussions - COMSOL Forums
Browsing all 3988 articles
Browse latest View live
↧

Problems with STEP FUNCTION

Hi everybody, I have an inlet in a water reactor working in the following way: 10 s on, 80 s off, 10 s on, 80 s off.... -Fist of all, I have built a PIECEWISE (pw1) function (0<t<10 = 1,...

View Article


Problem with Automatic Remeshing / MUMPS allocation factor increased to 1.44.

Hi there, I have built a COMSOL 2D model that uses deformed geometry, where the geometry movement is non uniform. I need to use Automatic Remeshing to update the mesh elements. But after some time (t =...

View Article


Coupling transport of a species to surface reactions

Hello, I am trying to make a model that has laminar flow, transport of a dilute species, and surface reactions. I want the laminar flow and transport of a dilute species to distribute the chemical...

View Article

constraining the range of dependent variables

Hello, I have implemented an axisymmetric drift-diffusion equation using the equation-based modeling interface in COMSOL 4.3 (incorporating the necessary terms due to the curvilinear coordinates). I...

View Article

Geometry building differently during Batch Sweeps than in individual simulations

COMSOL'ers: I have a geometry of a V-antenna which builds properly as a function of angle ("del") when simulated individually; however, when run under a batch sweep (of del) the geometry does not...

View Article


Electrostatic and transport of diluted species coupling to an IPMC sensor model

Dear community, I am trying to build a simulation of an Ionic Polymer Metal Composite (IPMC) strip sensor, a thin membrane of polymer ionic on witch too thin gold electrodes are plated. It is a 2D time...

View Article

Help with modeling resistance in current collectors for lithium-ion

Hello, I am not sure if I am in the correct area of this forum for assistance I need. I am currently working on a model for current collectors in lithium-ion batteries. More specifically the voltage...

View Article

Problem with Automatic Remeshing / MUMPS allocation factor increased to 1.44.

Hi there, I have built a COMSOL 2D model that uses deformed geometry, where the geometry movement is non uniform. I need to use Automatic Remeshing to update the mesh elements. But after some time (t =...

View Article


Combine two solutions

Hey all, I have two consecutive time dependent studies and two solutions sol1 and sol2. In postprocessing I would now like to "stitch" these two solutions together, so that instead of having to deal...

View Article


How evaluate time when a variable assumes a given value

Hi, It is known that the function "at" evaluates a function for a specific time value. Ex: at(1.5s, u). However, I'm looking for a way to get the instant of time (tx) when a variable (Var) (such as...

View Article

NLfail despite low tolerances using fully coupled approach

Hi, I try to observe the heating of a system using an electric pulse, i.e. Joule heating (--> Laplace equation and heat equation). The conductivity of the material of interest depends on the local...

View Article

Best Way to Incident Electric Field

I'm currently working on modeling a 2D gradient index metamaterial lens and studying the electric field intensity inside it. My geometry consists of vertical alternating layers of two different...

View Article

Initial values from solution and user defined for some variable.

Dear all, First I want to thank all the people that contribute to this community, which is very helpful for first hand experience user. I find myself in a situation where there is the need to specify...

View Article


Can Comsol solve two physics with a common variable together?

Hello I am trying to couple Heat Transfer and Transport of Concentrated Species together. They both have a common variable dependency. I have to put a mass flux in a water-air interface and, the mass...

View Article

Comsol Cluster Computing Problem !

Hi, when i am about to choose three nodes of which are at the settings of comsol cluster, it says "process status" scheduling and it stucks like that. when i am about to choose two nodes, comsol...

View Article


Impose a limitation for solving an equation

Hi, I'm using general PDE in COMSOL. I want to solve the equation by this condition: The calculated main variable in each time step can not decrease, in other words if A is the main variable, then...

View Article

Time study simulation

Hi, In time dependent study simulation in COMSOL, we need to define range in study setting as below: range(time1, TIME, time2) This means that the simulation will be study between time1 and time2, the...

View Article


How to set a max and min to the main variable in General form PDE

Hi, I really need somebody help me. How can I set a max and min value to the main variable in General form PDE? Thanks, Arezoo

View Article

Simulation Based on previous simulation results

I am working on an RF MEMS Switch, I used electromechanics physics and got its results. Now I want to simulate its RF Performance using Electromagnetic Waves, Frequency Domain physics, but based on the...

View Article

Problems with STEP FUNCTION

Hi everybody, I have an inlet in a water reactor working in the following way: 10 s on, 80 s off, 10 s on, 80 s off.... -Fist of all, I have built a PIECEWISE (pw1) function (0<t<10 = 1,...