Parameter study and using probes

$
0
0
Hi,

I am trying to conduct a parameter study and I want to measure the pressure in my model at certain points by using probes. The problem I have in the moment is that all the probes return NaN.

So, I defined a parameter I want to change under the global definitions node and I used this parameter in the parametric sweep node (under study). Furthermore I chose accumulated probe table, use all probes and keep solutions in memory: only last. I also created a frequency domain step (under study) in which I defined the frequencies I want to calculate. The only way that the probes do not return NaN is to choose store fields in output: all. But this also creates a field output for every frequency I investigate which takes too much storage at the cluster we use. Does anybody know how to only obtain the probe values?

When I am using no parameteric sweep node and only the frequency domain node and under this I choose store fields in output: for selections (which I do not have), I only get the probe results without the field output and the result is not NaN but a compley number, which I want to have. So, why does it work here but not when using the parametric sweep node...

Any help is greatly appreciated!

Best regards,

Peter