Hi dear Ivar
Thank you for Kindness
I used your advice and simulated my wire in mfh, and feed time dependent current to the wire with "external current density", but it doesn't work correctly.
So I simulate my 3D infinite wire with coupling "magnetic field" and "electric current" in time dependent study. Then I feed current into wire with "terminal" and "ground" in "electric current". Then couple it with "magnetic field" by "external current density" and "ec.Jx, ec.Jy, ec.Jz" variables or couple it with "linear multi turn coil" and "ec.normJ*1[mm^2]". But again result of magnetic field isn't correct and result of this according to finite wire.
I attached figure of my simulation for you. Please check it and inform me how can I change result according to infinite wire.
Thank you so much and with best regards
Thank you for Kindness
I used your advice and simulated my wire in mfh, and feed time dependent current to the wire with "external current density", but it doesn't work correctly.
So I simulate my 3D infinite wire with coupling "magnetic field" and "electric current" in time dependent study. Then I feed current into wire with "terminal" and "ground" in "electric current". Then couple it with "magnetic field" by "external current density" and "ec.Jx, ec.Jy, ec.Jz" variables or couple it with "linear multi turn coil" and "ec.normJ*1[mm^2]". But again result of magnetic field isn't correct and result of this according to finite wire.
I attached figure of my simulation for you. Please check it and inform me how can I change result according to infinite wire.
Thank you so much and with best regards